在线留言
|
Model |
Marking |
|
|
|
|
|
Maximum |
Resistance |
||
V max |
Imax |
I hold |
I trip |
Pd |
Time To Trip |
|||||
|
|
@ |
@ |
Typ. |
Current |
Time |
R i min |
R1max |
||
(Vdc) |
(A) |
(A) |
(A) |
(W) |
(A) |
(Sec) |
(W) |
(W) |
||
SMD0805R005SF |
1 |
15.0 |
30 |
0.05 |
0.15 |
0.5 |
0.5 |
1.50 |
1.500 |
18.000 |
SMD0805R010SF |
1 |
15.0 |
100 |
0.10 |
0.30 |
0.5 |
0.5 |
1.50 |
0.750 |
6.000 |
SMD0805R020SF |
2 |
9.0 |
30 |
0.20 |
0.50 |
0.5 |
8.0 |
0.02 |
0.550 |
3.500 |
SMD0805R035SF |
3 |
6.0 |
100 |
0.35 |
0.75 |
0.5 |
8.0 |
0.10 |
0.200 |
1.200 |
SMD0805R035SF12v |
3 |
12.0 |
30 |
0.35 |
0.75 |
0.5 |
8.0 |
0.10 |
0.200 |
1.200 |
SMD0805R050SF |
5 |
6.0 |
30 |
0.50 |
1.00 |
0.5 |
8.0 |
0.10 |
0.100 |
0.850 |
SMD0805R050SF12v |
5 |
12.0 |
30 |
0.50 |
1.00 |
0.5 |
8.0 |
0.10 |
0.100 |
0.850 |
SMD0805R050SF16v |
5 |
16.0 |
30 |
0.50 |
1.00 |
0.5 |
8.0 |
0.10 |
0.100 |
0.850 |
SMD0805R050SF24v |
5 |
24.0 |
30 |
0.50 |
1.00 |
0.5 |
8.0 |
0.10 |
0.100 |
0.850 |
SMD0805R075SF |
7 |
6.0 |
35 |
0.75 |
1.50 |
0.6 |
8.0 |
0.20 |
0.070 |
0.385 |
SMD0805R075SF12v |
7 |
12.0 |
35 |
0.75 |
1.50 |
0.6 |
8.0 |
0.20 |
0.070 |
0.385 |
SMD0805R100SF |
0 |
6.0 |
35 |
1.00 |
1.95 |
0.6 |
8.0 |
0.30 |
0.040 |
0.230 |
SMD0805R100SF12v |
0 |
12.0 |
35 |
1.00 |
1.95 |
0.6 |
8.0 |
0.30 |
0.040 |
0.230 |
SMD0805R110SF |
0 |
6.0 |
35 |
1.10 |
2.20 |
0.6 |
8.0 |
0.30 |
0.035 |
0.210 |
SMD0805R110SF12v |
0 |
12.0 |
35 |
1.10 |
2.20 |
0.6 |
8.0 |
0.30 |
0.035 |
0.210 |
SMD0805R125SF |
12 |
6.0 |
35 |
1.25 |
2.50 |
1.5 |
8.0 |
0.60 |
0.025 |
0.140 |
SMD0805R150SF |
15 |
6.0 |
30 |
1.50 |
3.00 |
1.0 |
8.0 |
0.50 |
0.015 |
0.130 |
V max = Maximum operating voltage device can withstand without damage at rated current (Imax).
I max = Maximum fault current device can withstand without damage at rated voltage (V max).
I hold = Hold Current. Maximum current device will not trip in
I trip = Trip Current. Minimum current at which the device will always trip in
Pd = Power dissipation when device is in the tripped state in
Ri min/max = Minimum/Maximum device resistance prior to tripping at
R1max = Maximum device resistance is measured one hour post reflow.
CAUTION : Operation beyond the specified ratings may result in damage and possible arcing and flame.