在线留言
|
Model |
Marking |
|
|
|
|
|
Maximum |
Resistance |
||
V max |
Imax |
I hold |
I trip |
Pd |
Time To Trip |
|||||
|
|
@ |
@ |
Typ. |
Current |
Time |
R i min |
R1max |
||
(V dc) |
(A) |
(A) |
(A) |
(W) |
(A) |
(Sec) |
(W) |
(W) |
||
SMD1210R005SF |
RA |
30.0 |
100 |
0.05 |
0.15 |
0.6 |
0.25 |
1.50 |
2.800 |
50.000 |
SMD1210R010SF |
R1 |
30.0 |
100 |
0.10 |
0.30 |
0.6 |
0.50 |
0.60 |
0.800 |
15.000 |
SMD1210R020SF |
R2 |
30.0 |
100 |
0.20 |
0.40 |
0.6 |
8.0 |
0.02 |
0.400 |
5.000 |
SMD1210R035SF |
R3 |
6.0 |
100 |
0.35 |
0.75 |
0.6 |
8.0 |
0.20 |
0.200 |
1.300 |
SMD1210R035SF16v |
R3 |
16.0 |
100 |
0.35 |
0.75 |
0.6 |
8.0 |
0.20 |
0.200 |
1.300 |
SMD1210R050SF |
R5 |
13.2 |
100 |
0.50 |
1.00 |
0.6 |
8.0 |
0.10 |
0.180 |
0.900 |
SMD1210R050SF24v |
R5 |
24.0 |
100 |
0.50 |
1.00 |
0.6 |
8.0 |
0.10 |
0.180 |
0.900 |
SMD1210R075SF |
R7 |
6.0 |
100 |
0.75 |
1.50 |
0.6 |
8.0 |
0.10 |
0.070 |
0.400 |
SMD1210R075SF16v |
R7 |
16.0 |
100 |
0.75 |
1.50 |
0.6 |
8.0 |
0.10 |
0.070 |
0.400 |
SMD1210R110SF |
R0 |
6.0 |
100 |
1.10 |
2.20 |
0.6 |
8.0 |
0.30 |
0.050 |
0.210 |
SMD1210R110SF |
R0 |
16.0 |
35 |
1.10 |
2.20 |
0.6 |
8.0 |
0.30 |
0.050 |
0.210 |
SMD1210R150SF |
RX |
6.0 |
100 |
1.50 |
3.00 |
0.6 |
8.0 |
0.50 |
0.030 |
0.110 |
SMD1210R150SF12v |
RX |
12.0 |
100 |
1.50 |
3.00 |
0.6 |
8.0 |
0.50 |
0.030 |
0.110 |
SMD1210R175SF |
RY |
6.0 |
100 |
1.75 |
3.50 |
0.8 |
8.0 |
0.60 |
0.020 |
0.080 |
SMD1210R200SF |
RZ |
6.0 |
100 |
2.00 |
4.00 |
0.8 |
8.0 |
1.00 |
0.015 |
0.070 |
SMD1210R260SF |
R— |
6.0 |
100 |
2.60 |
5.20 |
0.8 |
8.0 |
2.00 |
0.010 |
0.060 |
V max = Maximum operating voltage device can withstand without damage at rated current (Imax).
I max = Maximum fault current device can withstand without damage at rated voltage (V max).
I hold = Hold Current. Maximum current device will not trip in
I trip = Trip Current. Minimum current at which the device will always trip in
Pd = Power dissipation when device is in the tripped state in
Ri min/max = Minimum/Maximum device resistance prior to tripping at
R1max = Maximum device resistance is measured one hour post reflow.
CAUTION : Operation beyond the specified ratings may result in damage and possible arcing and flame.