0805 Resettable Fuses
  • Product introduction
  • Electrical characteristics
  •  V max  = Maximum operating voltage device can withstand without damage at rated current (Imax).

     I max   = Maximum fault current device can withstand without damage at rated voltage (V max).

     I hold   = Hold Current. Maximum current device will not trip in 25°C still air.

     I trip    = Trip Current. Minimum current at which the device will always trip in 25°C still air.

     Pd      = Power dissipation when device is in the tripped state in 25°C still air environment at rated voltage.

     Ri min/max  = Minimum/Maximum device resistance prior to tripping at 25°C.

     R1max  = Maximum device resistance is measured one hour post reflow.

     CAUTION : Operation beyond the specified ratings may result in damage and possible arcing and flame.

     V max  = 元件在額定電流下能承受的最大電壓.

     I max   =元件在額定電壓下能承受的最大電流.

     I hold   = 25℃靜止空氣環境中,產品不動作的最大電流.

     I trip    = 25℃靜止空氣環境中,最小動作電流.

  • Model

    Marking

     

     

     

     

     

    Maximum

    Resistance

    V max

    Imax

    I hold

    I trip

    Pd

    Time To Trip

     

     

    @25°C

    @25°C

    Typ.

    Current

    Time

    R i min

    R1max

    (Vdc)

    (A)

    (A)

    (A)

    (W)

    (A)

    (Sec)

    (W)

    (W)

    SMD0805R005SF

    1

    15.0

    30

    0.05

    0.15

    0.5

    0.5

    1.50

    1.500

    18.000

    SMD0805R010SF

    1

    15.0

    100

    0.10

    0.30

    0.5

    0.5

    1.50

    0.750

    6.000

    SMD0805R020SF

    2

    9.0

    30

    0.20

    0.50

    0.5

    8.0

    0.02

    0.550

    3.500

    SMD0805R035SF

    3

    6.0

    100

    0.35

    0.75

    0.5

    8.0

    0.10

    0.200

    1.200

    SMD0805R035SF12v

    3

    12.0

    30

    0.35

    0.75

    0.5

    8.0

    0.10

    0.200

    1.200

    SMD0805R050SF

    5

    6.0

    30

    0.50

    1.00

    0.5

    8.0

    0.10

    0.100

    0.850

    SMD0805R050SF12v

    5

    12.0

    30

    0.50

    1.00

    0.5

    8.0

    0.10

    0.100

    0.850

    SMD0805R050SF16v

    5

    16.0

    30

    0.50

    1.00

    0.5

    8.0

    0.10

    0.100

    0.850

    SMD0805R050SF24v

    5

    24.0

    30

    0.50

    1.00

    0.5

    8.0

    0.10

    0.100

    0.850

    SMD0805R075SF

    7

    6.0

    35

    0.75

    1.50

    0.6

    8.0

    0.20

    0.070

    0.385

    SMD0805R075SF12v

    7

    12.0

    35

    0.75

    1.50

    0.6

    8.0

    0.20

    0.070

    0.385

    SMD0805R100SF

    0

    6.0

    35

    1.00

    1.95

    0.6

    8.0

    0.30

    0.040

    0.230

    SMD0805R100SF12v

    0

    12.0

    35

    1.00

    1.95

    0.6

    8.0

    0.30

    0.040

    0.230

    SMD0805R110SF

    0

    6.0

    35

    1.10

    2.20

    0.6

    8.0

    0.30

    0.035

    0.210

    SMD0805R110SF12v

    0

    12.0

    35

    1.10

    2.20

    0.6

    8.0

    0.30

    0.035

    0.210

    SMD0805R125SF

    12

    6.0

    35

    1.25

    2.50

    1.5

    8.0

    0.60

    0.025

    0.140

    SMD0805R150SF

    15

    6.0

    30

    1.50

    3.00

    1.0

    8.0

    0.50

    0.015

    0.130

    V max  = Maximum operating voltage device can withstand without damage at rated current (Imax).

        I max   = Maximum fault current device can withstand without damage at rated voltage (V max).

        I hold   = Hold Current. Maximum current device will not trip in 25°C still air.

        I trip    = Trip Current. Minimum current at which the device will always trip in 25°C still air.

        Pd      = Power dissipation when device is in the tripped state in 25°C still air environment at rated voltage.

        Ri min/max  = Minimum/Maximum device resistance prior to tripping at 25°C.

        R1max  = Maximum device resistance is measured one hour post reflow.

        CAUTION : Operation beyond the specified ratings may result in damage and possible arcing and flame.